ISO 7886-3 PDF

Objetivo: ISO specifies the properties and performance of sterile single-use hypodermic syringes with or without needle, made of plastic materials . Find the most up-to-date version of ISO at Engineering Sterile hypodermic syringes for single use – Part 3: Auto-disable syringes for fixed -dose immunization (ISO ); German version EN ISO

Author: Takazahn Gardacage
Country: Saudi Arabia
Language: English (Spanish)
Genre: History
Published (Last): 15 January 2007
Pages: 461
PDF File Size: 15.50 Mb
ePub File Size: 19.19 Mb
ISBN: 635-2-96935-257-3
Downloads: 8370
Price: Free* [*Free Regsitration Required]
Uploader: Mikagrel

Syringes with re-use prevention feature Get the latest version of this product.

NBN EN ISO | NBN

Water for analytical ido use — Specification and test methods ISO No part of the these publications may be reproduced in any form without the prior permission in writing of BIS. No secondary or additional action on the part of the user shall be required. For syringes ido integrated needle, 14,2 of ISO This part of ISO does not specify the design of the auto-disable feature, which is left to the discretion ofthe manufacturer. Certain conventions are, however, not identical to those used in Indian Standards.

Using the test device C.

Full text of ” IS Attention is particularly drawn to the following: The timing of the activation of the auto-disable feature may vary by design, typically within the ranges described below: The piston shall not become detached from the plunger when tested in accordance with Annex B of ISO Figure 1 — Schematic representation of auto-disable syringe for fixed dose IS Part 3: It is recognized that syringes designed to reduce the risk of needlestick injuries, in addition to preventing sharps injuries, may also comply with this part of standard with regard to their auto-disable properties, but it is stressed that anti-needlestick properties of syringes are not in themselves addressed in this standard.

  EN 50086-1 PDF

For undated references, the latest edition of the referenced document including any amendments applies. Connect the needle of the syringe to the rubber stopper of the tubing of the reservoir B.

You will be redirected to our e-shop where you can buy the document. Stop the plunger travel and readjust the recorder to zero. For dated references, only the edition cited applies.

It is important to us that you purchase the right document. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard. Details Norm ISO nr: This does not preclude the free use, in the course of implementing the standard, of necessary details, such as symbols and sizes, type or grade designations.

Syringes with re-use prevention feature This document has been re-assessed by the committee, and judged to still be up to date. Adjust the relative positions of the syringe and reservoir so that the water level in the reservoir is approximately level with the mid-point of the syringe barrel.

These syringes are not covered by Parts 1 and 2 of this standard. Details of which is given in National Annex A.

Autodisable syringes for fixed-dose immunization ISO The details of conditions under which the licence for the use of the Standard Mark 786-3 be granted to manufacturers or producers may be obtained from the Bureau of Indian Standards.

NOTE Annex B gives a suggested test method and performance criteria for the forces required to move the plunger.

  HUMAN LOCOMOTION MICHAUD PDF

These lines shall be of uniform thickness. Follow these links to find other Standards similar to the one you are viewing. International Standard ISO Do you want to buy this document? Needle tubing shall be in accordance with ISO International Classification for Standards ICS is an international classification system for technical standards.

МКС EN ISO 7886-3:2011

For the purpose of deciding whether a particular requirements of this standard is complied with, the final value, observed or calculated expressing the result of a test or analysis, shall be rounded off in accordance with IS 2: When a syringe with integrated needle is tested in accordance with Annex 8 of ISO Standards are also reviewed periodically; a standard alongwith amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision.

Adjust the relative positions of the syringe and reservoir so that the water level in the reservoir is approximately level with the mid-point of the syringe barrel- B. IS Part 3: This part of JSO is not applicable to syringes for use with insulin specified in ISOsyringes made of glass specified in ISOsyringes for use with power-driven syringe pumps specified in ISOauto- disable syringes for variable dose delivery and syringes designed to be prefilled.

Review of Indian Standards Amendments are issued to standards as the need arises on the basis of comments.